Precision Distribution Monitoring Solution for IDC
Solutions

Precision Distribution Monitoring Solution for IDC

2024-08-22

Application

It is necessary to real-time monitor and centralize power consumption in data center and data can be displayed on HMI,and uploaded to the power and environment monitoring system by RS485 on touch screen and realize real-time monitoring of whole power distribution system. At the same time, it can realize energy efficiency analysis to reduce energy consumption.

Structure

structure-1qfrstructure-29hmstructure-3ou7structure-4s7o

Function

1. Incoming line and outgoing line circuits independent monitoring modules.

2. Can measure up to 2 incoming line circuits and up to 192 outgoing line circuits current, voltage, power, energy and power quality.

3. Data centralized monitoring and display by HMI and data is uploaded to power and environment monitoring system through RS485.

4. For high voltage DC 240V or 336V system, insulation monitoring module can be added to monitor ground insulation resistance of main bus.

5. DC24V power supply for touch screen and outgoing line monitoring module(power supply from main module output ).

6. Communication:monitoring device by RS485, touch screen by RS485 or RJ45.

7. Certificate:CE.

Product Selection

Product name

Product image

Functions

ATP007kt ATP010kt touch screen

 ATP007bi1

● 7 or 10 inch touch screen
● Real-time monitoring and display voltage,current,power,energy,power quality,switch status,wave curve,etc. of the busbar
● Monitoring device alarm,communication and other parameters can be configured on the screen
● 2 RS485 and 1 Ethernet,and data can uploaded by RS485 or RJ45

AMC16Z-ZA data center AC incoming line monitoring device  AMC16Z-ZAoiv ● Designed specifically for the power supply management of server in the data center
● Measure A+B independent 2 channels three-phase inlet
● U, I, P, Q, S, PF, kWh, kvarh
● 2-63rd harmonic
● RS485, Modbus-RTU communication
● CE certification
● Din rail 35mm installation
AMC16Z-FAK24 data center AC outgoing line monitoring device  AMC16Z-FAK24d69 ● Designed specifically for the power supply management of server in the data center
● Power supply by AMC16Z-ZA
● Measure A+B independent 24 circuits
● U, I, P, Q, S, PF, kWh, kvarh
● 2-31st Harmonic
● RS485, Modbus-RTU communication
● Din rail 35mm installation
AMC16Z-FAK48 data center AC outgoing line monitoring device  AMC16Z-FAK24kb1 ● Designed specifically for the power supply management of server in the data center
● Measure A+B independent 48 circuits
● Power supply by AMC16Z-ZA
● U, I, P, Q, S, PF, kWh, kvarh
● 2-31st Harmonic
● RS485, Modbus-RTU communication
● Din rail 35mm installation
AMC16Z-ZD data center DC incoming line monitoring device  AMC16Z-ZDfow ● Designed specifically for the power supply management of server in the data center
● Measure A+B independent inlet circuit
● U, I, P, Q, S, PF, kWh, kvarh
● RS485, Modbus-RTU communication
● CE certification
● Din rail 35mm installation
AMC16Z-FDK24 data center DC outgoing line monitoring device  AMC16Z-FDK2437w ● Designed specifically for the power supply management of server in the data center
● Power supply by AMC16Z-ZD
● Measure A+B independent 24 circuits
● RS485, Modbus-RTU communication
● Din rail 35mm installation
● CE certification
AMC16Z-FDK48 data center DC outgoing line monitoring device  AMC16Z-FDK2474v ● Designed specifically for the power supply management of server in the data center
● Power supply by AMC16Z-ZD
● Measure A+B independent 48 circuits
● Power supply by AMC16Z-ZD
● RS485, Modbus-RTU communication
● Din rail 35mm installation
● CE certification
AKH-0.66/W AC outgoing line current transformer  AKH-0iof ● Current ratio:100A/50mA
● Common Specification:100A/50mA
AHKC-BS DC outgoing line hall effect current sensor  AHKC-BS88p ● Current ratio:100A/5V
● Common Specification:100A/5V