Single Phase AMC Series AC Digital Panel Meter
description1
description2
General
AMC series single phase programmable ammeters and voltmeters can measure voltage and current of single phase grid. It supports RS485 Modbus-RTU communication. It supports LCD digital display and 4~20mA analog output can be selected.
Detail

Product Parameter
Technical Parameter |
Value |
||
Input |
Rated value |
Voltage: AC100V or 400V, current: AC1A or 5A |
|
Overload |
Voltage: 1.2 times rated value(continuous) 2 times rated value(1 second) Current: 1.2 times rated value(continuous) 10 times rated value (1 second) |
||
Frequency |
45Hz~65Hz |
||
Power consumption |
<0.5VA |
||
Accuracy |
Class 0.5 |
||
Funct ion |
Display |
LED or LCD |
|
Communication |
RS485(Modbus-RTU) |
||
Alarm |
1 channel passive relay,contact capacity 3A/30VDC, 3A/250VAC |
||
Analog output |
DC4~20mA( load < 500Ω) |
||
Switching |
Input |
4 channels or 2 channels passive contact Input |
|
Output |
2 channels switching output, NO relay contact, capacity 3A/30VDC, 3A/250VAC |
||
Auxiliary power supply |
Voltage range |
AC/DC 85~265V |
|
Power consumption |
<5VA |
||
Insulation resistance |
≥100MΩ |
||
Environment |
Temperature |
Operating:-10°C~+55°C Storage: -25°C ~+70°C |
|
Humidity |
≤93%(no condensation) |
||
Altitude |
≤2500m |
||
Dimension

| Shape | Panel | Housing | Cut out | ||||
| Unit:mm | Width | Height | Width | Height | Depth | Width | Height |
| 48 Square | 49 | 49 | 44 | 44 | 93 | 45 | 45 |
| 72 Square | 75 | 75 | 66.5 | 66.5 | 94.3 | 67 | 67 |
| 96 Square | 96 | 96 | 86.5 | 86.5 | 77.8 | 88 | 88 |
Wiring

Installation
Diagram
Application
Packing&delivery

Product Selection
| Type | Basic function | Shape | Optiona function |
| AMC48-AI AMC48-AV |
Current,voltage measurement; LED |
48 Square | RS485 communication(/C) Analog output(/M) |
| AMC48-AI3 AMC48-AV3 |
None | ||
| AMC48L-AI AMC48L-AV |
Current,voltage measurement; LCD |
1.RS485 communication(/C) 2.Analog output(/M) |
|
| AMC48L-AI3 AMC48L-AV3 |
None | ||
| AMC72-AI AMC72-AV AMC72-AI3 AMC72-AV3 |
Current,voltage measurement; LED |
72 Square | 1.RS485 communication(/C) 2.Analog output(/M) 3.Alarmoutput(J) 4.Analog output +RS485 communication(MC) 5.RS485 communication +switching output 2DI2DO(/KC) 6.Alarm output +analog output +RS485 communication(JMC) |
| AMC72-DI AMC72-DV |
DC voltage,current measurement; LED |
||
| AMC72L-AI AMC72L-AV AMC72L-AI3 AMC72L-AV3 |
Current,voltage measurement; LCD |
||
| AMC72L-DI AMC72L-DV |
DC voltage,current measurement; LCD |
||
| AMC96-AI AMC96-AV AMC96-AI3 AMC96-AV3 |
Current,voltage measurement LED |
96 Square | 1.RS485 communication(/C) 2.Analog output(/M or/3M) 3.Alarm output(/J) 4.Analog output +RS485 communication(/MC or/M3C) 5.RS485 communication +switching 4DI2DO (/KC) 6.Alarm output+analog output +RS485 communication(JMC) |
| AMC96L-AI AMC96L-AV AMC96L-Al3 AMC96L-AV3 |
Current,voltagemeasurement; LCD |
||
|
Note:1.AI/AV means single-phase current/voltage,Al3/AV3 means three-phase current/voltage; 2./Jmeans 1 channel relay output(multiplexing with second channel switching output) | |||