Multi-loop LCD Display AC Energy Meter AMC200L for Tower Base Station
Download
description1
description2
General
AMC200(L) AC multi-loop intelligent power acquisition and monitoring device is mainly used for the measurement of full electrical parameters of multiple loops, and can access the current input of up to 8 three-phase loops or 24 single-phase loops at the same time. Can measure voltage and current, power, power factor and other parameters.
Feature
Meter Type |
Basic Function |
AMC200L-4E3 |
Can access 4 three-phase AC circuits at the same time, can directly measure the voltage, current, power, power factor and other parameters, 6 switching input (2 active, 4 passive), 2 switching output, 1 RS485, 4 NTC temperature, 1 temperature and humidity measurement, with liquid crystal display |
AMC200L-8E3 |
Can access 8 three-phase AC circuits at the same time, can directly measure the voltage, current, power, power factor and other parameters, 6 switching input (2 active, 4 passive), 2 switching output, 1 RS485, 4 NTC temperature, 1 temperature and humidity measurement, with liquid crystal display |
Dimension
Matching Transformers
Type |
Ratio |
Wire length |
Accuracy |
Installation method |
AKH-0.66/W-9NY 50A/20mA |
50A/20mA |
(1+0.2)m |
0.2 Class |
Closed type, RJ interface |
AKH-0.66/K-Φ10N 50A/20mA |
50A/20mA |
(1+0.2)m |
0.5 Class |
Split type, RJ interface |
AKH-0.66 Z-3/*Φ15Y(1/0.5) 100A/50mA |
100A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, trinity, RJ interface |
AKH-0.66/W-12NY 100A/50mA |
100A/50mA |
(1+0.2)m |
0.2 Class |
Closed type, RJ interface |
AKH-0.66/K-Φ16N 100A/50mA |
100A/50mA |
(1+0.2)m |
0.5 Class |
Split type, RJ interface |
AKH-0.66/W-20Y 200A/50mA |
200A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
AKH-0.66/K-Φ24N 200A/50mA |
200A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
AKH-0.66/W-20Y(1/0.5) 250A/50mA |
250A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
AKH-0.66/W-30NY 250A/50mA |
250A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
AKH-0.66/K-Φ24N 250A/50mA |
250A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
AKH-0.66-TD-Φ60-NY |
400A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
AKH-0.66/K-Φ36N 400A/50mA |
400A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
AKH-0.66-TD-Φ60-NY |
600A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
AKH-0.66/K-Φ36N 600A/50mA |
600A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
Installation
Wiring
Packing&delivery