Medical Intelligent Insulation Monitor AIM-M300/SG with Fault Locating Function
Medical IT Isolated Power System

Medical Intelligent Insulation Monitor AIM-M300/SG with Fault Locating Function

Auxiliary Power Supply: DC 18~36V

Resistance Measuring Range: 15~999kΩ

Current Monitoring Range: 2.1~60A

Thermal Resistor: 2 Pt100

Locate Voltage: ≤12V

Locate Current: ≤1mA (peak)

Fault Record: 20

Display Method: LCD

Communication: RS485(MODBUS-RTU); CAN

    General


    AIM-M300/SG medical intelligent insulation monitor adopts advanced micro-controller technology with high integration, compact size, easy installation, integrating intelligence, digitization and networking, and is suitable for insulation monitoring and fault localization of isolated power supply system in medical group 2 places, such as operating rooms, intensive care units and so on.

    LCD Display


    feature.png

    Product Parameter


    Electric Performance 

    Auxiliary power supply Voltage DC 18~36V
    Power consumption ≤6W
    Insulation monitoring Resistance measuring range 15~999kΩ
    Response value 50~999kΩ
    Response time ≤3s
    Measuring voltage ≤13V
    Current monitoring Measuring value 2.1~60A
    Measuring accuracy ±5%
    Alarm value 5~80A
    Temperature monitoring Thermal resistor 2Pt100
    Measuring range -50℃~200℃
    Alarm value range 0~200℃
    Locate signal Locate voltage ≤12V
    Locate current ≤1mA(peak)
    Alarm output Output mode 2 output relay
    Contact rating AC 250V/3A, DC 30V/3A
    Communication RS485(MODBUS-RTU); CAN
    Insulation method Guide
    Display method LCD, LED
    Fault record 20

    Working Environment

    Temperature range Operating -10℃~55℃
    Storage -25℃~70℃
    Transport -25℃~70℃
    Relative humidity <95%, no condensation
    Altitude <2500m

    Dimension(unit:mm)


    dimension.png

    Wiring


    Upper row of terminals: 24V, G for the auxiliary power supply, L1, L2 and the monitored IT system connection (can be connected to the two outputs of the isolation transformer), I0, I1 for the signal input of the current transformer, T0, T1 for the signal input of the temperature sensor, FE, KE for the function of the grounding line, wiring should be used to connect the two independent of each other and the site of the equipotential terminal block.

    wiring.png

    Installation


    installation.png

    Diagram


    diagram.png