DC Intelligent Power Panel Meter PZ72L-DE
description1
description2
General
PZ series intelligent DC energy meter is designed for applications such as DC panels, solar power, telecommunications base stations, and charging posts. This series of instruments can measure voltage, current, power, forward and reverse power in DC system. It can be used for local display, and connected with industrial control equipment, computers, form a measurement and control system. And it has a variety of external excuse functions for the user to choose: RS485 communication interface, Modbus-RTU protocol, relay alarm output, digital input/output. According to different requirements, through the instrument panel keys, you can set the ratio, communication parameters.
The product meets the relevant technical requirements of the standard Q/GDW1825-2013 DC power meter specification,GB/T29318-2012 Non-vehicle charging electric energy metering for electric vehicles, Q/GDW364-2009 Single-phase energy meter specification.
LCD Display
Feature
Parameter
Input voltage |
DC voltage |
Input range |
Direct access: 0 ~100V,0 ~500V,0 ~1000V |
Input resistance |
≥6kΩ/V |
||
DC voltage |
Input range |
Indirect access:0-2500A(External Shunt or Hall Current Sensor, the range can be set) |
|
Shunt |
75mV |
||
Hall Current Sensor |
0 ~20mA、0 ~5V |
||
Power consumption |
≤1mW |
||
Overload |
It can work at normal status at 1.2 times of full load, and can continued work 1 second at 2 times of full load. |
||
Accuracy class |
0.5class |
||
Pulse constant |
Voltage and current specifications:750V、300A ,Default pulse constant:100imp/kWh |
||
Voltage and current specifications :1000V、300A ,Default pulse constant:100imp/kWh | |||
Function |
Measuring |
Voltage、Current、Power |
|
Calculate |
Current total electricity、Current positive energy、Current reverse power |
||
Multiple rate |
Four time zones、two time table、fourteen time points、four multiple rates. (PZ72L-DE support only) |
||
Historical data statistics |
Last 12 months of historical electricity(multiple rate electricity).(PZ72L-DE support only) |
||
DI、DO |
PZ72 has two digital outputs and two digital inputs, PZ96 has two digital outputs and four digital inputs. DI(Collect and display local switch status information、Realize remote transmission by RS485)、DO(Relay output, can achieve "remote control" and alarm output) |
||
Display |
LCD(the backlight delay time can be adjusted) or LED |
||
Communication |
RS485、Half duplex、Photoelectric isolation、Modbus-RTU / DL/T645-07、Band:1200/2400/4800/9600、Infrared :1200 |
||
DI、DO |
DI |
Dry contact input, Meter built-in power supply, photoelectric isolation |
|
DO |
Two relay outputs, Normally open contact, capacity:2A/30VDC or 2A/250VAC |
||
Working power |
Voltage range |
85 ~265VAC/DC、50/60Hz;20 ~60VDC |
|
Power consumption |
≤2W |
||
Insulation resistance |
≥100MΩ |
||
Power frequency withstand voltage |
3kV/1min(RMS)(between the power supply binding post and the signal binding post) |
||
Environment |
Temperature |
working:-25℃~+60℃; storage:-20℃~+70℃ |
|
Humidity |
≤ 93%RH ,No condensation, no corrosive gases |
||
Altitude |
≤ 2500m |
||
Dimension

Outline(unit:mm) |
Panel Size |
Housing Size |
Cut-out |
||||
Width |
Height |
Width |
Height |
Depth |
Width |
Height |
|
72 square |
75 |
75 |
66 |
66 |
98 |
67 |
67 |
96 square |
96 |
96 |
86 |
86 |
92 |
88 |
88 |
Wiring