AHKC-LT Closed Type Hall Effect Current Transducer
description1
description2
Product introduction
Rated input current:AC/DC0~(100-800)A
Rated output voltage:5V/4V
Measuring Aperture:32.5mm
Power supply:±15V
Size / Dimension:90*73.5*25mm
Accuracy: 1.0
Zero offset voltage: ±20mV
Offset current drift: ≤±2.0mV/ºC
Linearity: ≤0.2%FS
Response time: ≤5us
Frenquency: 0~20kHz
Insulation voltage: 2.5kV/50Hz/1min
Power consumption:≤0.5W
Dimension

Wiring

Application

Packing&delivery

Precautions
1. When the Hall sensor is used, attention must be paid to the coupling between the primary side coil and assistant side coil in order to get better dynamic characteristics and sensitivity, single conductor that should cram the thread hole of Hall sensor module completely is proposed to use.
2. When the Hall sensor is used, the best measuring accuracy can be got under rated input current value. When the measured current is much less than the rated value, the primary side can use multi-turns if want to obtain the best accuracy, that is IpNp=rated ampere-turns. In addition, the temperature of the primary side feeder line cannot be more than 80℃.
3. When the Hall current sensor is working normally, the auxiliary power supply cannot be more than ±20% of calibration value.
4. The Hall Current sensor is strictly prohibited to be fallen from high place (≥1m) during installation and use.
5. Zero and full scale regulator potentiometer can not be adjusted.
6. Auxiliary power supply is required to be deployed voluntarily.
7. Power positive and negative poles cannot be inversely connected.