AC Three Phase Multi-function Panel Power Meter AMC96L-E4/KC(AMC72L-E4/KC)
description1
description2
General
AMC series intelligent power collection and monitoring device is a smart meter designed for power monitoring needs of power systems, industrial and mining enterprises, utilities, and intelligent buildings.
It integrates measurement of power parameters (such as sigle phase or three phase current, voltage, and active power). Power, reactive power, apparent power, frequency, power factor and power monitoring and assessment management. At the same time, it has a variety of peripheral interface functions for users to choose: with RS485 communication interface, MODBUS-RTU protocol can meet the needs of communication network management; 4-20mA analog output can correspond to measured electrical parameters, meet DCS such interface requirements; with switch input and relay output can realize the function of "remote signal" and "remote control" of circuit breaker switch.High-brightness LED/LCD display interface,parameter setting and control through buttons, ideal for real-time power monitoring systems. Can directly replace conventional power transmitters and measuring instruments. As an intelligent, digital front-end asquisition component, the instrument has been widely used in various control system, SCADA systems and energy management systems.
Detail


Product Parameter
Technical Parameter |
Value |
||
Input |
Connection |
3 phase 4 wire |
|
Frequency |
45~65Hz |
||
|
Voltage |
Rating:AC 100V,400V,660(690V, only AMC96L type) |
||
|
Overload: 1.2 times rated value(continuous); 2 times rated value(1 second) | |||
Power consumption:< 0.5VA | |||
Current |
Rating: AC 1A,5A |
||
|
Overload: 1.2 times rated value(continuous); 10 times rated value (1 second) | |||
Power consumption:< 0.5VA | |||
Output |
Energy |
Pulse width:80±20ms |
|
Pulse constant: 10000,40000,160000 imp/kWh | |||
Communication |
RS485(Modbus-RTU) |
||
Function |
Switching input |
2 channels or 4 channels passive contact input mode |
|
Switching output |
Output mode:2 channel relay NO contact output |
||
Analog output |
Contact capacity: 3A/30V DC, 3A/250VAC 0~5V,0~20mA,4~20mA programmable |
||
Accuracy |
Frequency:0.05Hz,current,voltage:class 0.2, reactive power:class 1.0,reactive energy:class 1.0,other:class 0.5,2~31st harmonic :±1% |
||
Auxiliary power supply |
AC/DC 85~265V |
||
Power consumption |
≤10VA |
||
Insulation resistance |
≥100MΩ |
||
Environment |
Temperature |
Operating: -10°C~+55°C Storage: -25°C ~+75°C |
|
Humidity |
≤93%(no condensation) |
||
Altitude |
≤2500m |
||
Dimension

| Shape | Panel | Housing | Cut out | ||||
| Unit:mm | Width | Height | Width | Height | Depth | Width | Height |
| 72 Square | 75 | 75 | 66.5 | 66.5 | 94.3 | 67 | 67 |
| 96 Square | 96 | 96 | 86.5 | 86.5 | 77.8 | 88 | 88 |
Wiring

AC Voltage Signal (400V or 660V AC L-L) Input via direct Connection & AC Current Signal (5A or 1A AC) input via -/5A AC or -/1A AC CTs (3-phase 4-wire)

AC Voltage Signal (400V or 660V AC L-L) Input via direct Connection & AC Current Signal (5A or 1A AC) input via -/5A AC or -/1A AC CTs (3-phase 3-wire)

AC Voltage Signal (100V AC L-L) Input via -/100V AC PTs & AC Current Signal (5A or 1A AC) input via -/5A AC or -/1A AC CTs (3-phase 4-wire)

AC Voltage Signal (100V AC L-L) Input via -/100V AC PTs & AC Current Signal (5A or 1A AC) input via -/5A AC or -/1A AC CTs (3-phase 3-wire)
Installation
Diagram
Application
Packing&delivery

Product selection
Type
Basic function
Shape
Optional function
AMC72-E
Single phase energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LED;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
72 Square
/C: RS485(Modbus-RTU)
/K: 2DI/2DO
/J: alarm
/KM: 2DI/2DO/1M
AMC72L-E
Single phase energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LCD;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
AMC72-E4/KC
Three phase energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LED;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
/H: THDi, THDu,2-31st harmonic
/SOE: event record
/K:4DI/2DO
/KM: 2DI/2DO/1M
AMC72L-E4/KC
Three phase energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LCD;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
AMC96-E3/KC
Three phase three wire energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LED;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
96 Square
/H: THDi.THDu,2-31st harmonic
/2M: 2 analog output(When 2M is selected, theswitching function is 2Dl/2DO)
AMC96L-E3/KC
Three phase three wire energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LCD;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
AMC96-E4/KC
Three phase four wire energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LED;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
/H: THDi.THDu,2-31st harmonic
/SOE: event record
/2M: 2 analog output(When 2M is selected, theswitching function is 2Dl/2DO)
AMC96L-E4/KC
Three phase four wire energy meter;
I, U, kW, kvar, kVA, kWh, kvarh, Hz;
LCD;
1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645
| Type | Basic function | Shape | Optional function |
| AMC72-E |
Single phase energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LED; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |
72 Square |
/C: RS485(Modbus-RTU) /K: 2DI/2DO /J: alarm /KM: 2DI/2DO/1M |
| AMC72L-E |
Single phase energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LCD; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |
||
| AMC72-E4/KC |
Three phase energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LED; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |
/H: THDi, THDu,2-31st harmonic /SOE: event record /K:4DI/2DO /KM: 2DI/2DO/1M |
|
| AMC72L-E4/KC |
Three phase energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LCD; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |
||
| AMC96-E3/KC |
Three phase three wire energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LED; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |
96 Square |
/H: THDi.THDu,2-31st harmonic /2M: 2 analog output(When 2M is selected, theswitching function is 2Dl/2DO) |
| AMC96L-E3/KC |
Three phase three wire energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LCD; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |
||
| AMC96-E4/KC |
Three phase four wire energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LED; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |
/H: THDi.THDu,2-31st harmonic /SOE: event record /2M: 2 analog output(When 2M is selected, theswitching function is 2Dl/2DO) |
|
| AMC96L-E4/KC |
Three phase four wire energy meter; I, U, kW, kvar, kVA, kWh, kvarh, Hz; LCD; 1 channel RS485 interface/Modbus-RTU protocol and the statute DTL645 |